Solar Inverter

UTL Gamma Solar PCU 2KVA 24V Price Specification

UTL Gamma Solar PCU 2KVA 24V Price Specification

Gamma PCU is a Solar Power Conditioning Unit (PCU) which uses Solar energy (primary) and also the power from grid (secondary), to charge the batteries. Since usage of power from grid is secondary, grid power is only used when solar energy is not present and battery voltage level reduces to a certain level. Grid power is also needed when solar power is reduced to a certain level and battery voltage is reduced to a certain level.

GAMMA PCU has the following advance features like DSP base design built in MPPT solar charge controller. , Most advanced LCD features. , Maximum preference to solar. Smart PCU , Capability of 100% panel rating. , Compatible with all PV arrays having different no. of cells.(36 cell/60 cell/72 cell). , Lightning protection . High efficiency MPPT and Inverter.

Specifications

Model UTL Gamma 2KVA 24V
Capacity 2000 VA
Operating DC Voltage 24 V
Switching Element MOSFET
Charger Topology BOOST MOSFET

Solar

Switching Element IGBT
Type of Charger PWM with MPPT
Efficiency ≥ 95%
Input Voltage Range (Min – Max)Voc 90-230
Maximum PV Power Recommended 2000  Watt

Battery

Battery Required 12 V X 2 ( 24 v )
Grid Disconnect (Solar Available) @14.5/Battery for 2 minutes or 13.5/Battery -100% Current
Grid Connect (PCU Mode/Smart Mode) 11.5 V
Temp. Compensation @3mV/cell ;  18mV/Battery
Battery Connection 2 Battery of  12 V Connection in Series

Grid

Nominal Grid Voltage 230 V
Battery Low Buzzer 10.2 V
Battery Low Cut 10 V
Battery High Cut 15.5 V
Solar Panel Charging Voltage 14.5 V
Solar Panel Current 18 A
Grid Charging Voltage 14.2 V
Grid Charging Current 10 A
Grid Reconnect @ Battery Voltage 11.8 V
Grid Low Cut Voltage – It Mode 175V±10V (ENABLE) , 120V±10V (DISABLE)
Grid High Cut Voltage – IT Mode 255V±10V (ENABLE) , 280V±10V (DISABLE)
IT Load Enable/Disable
Operating Mode Smart/PCU/Hybrid
Output Voltage Low 185 V
Output Voltage High 260 V

Inverter

Output  Phase Single Phase
Nominal Output  Voltage 230 V*
Nominal/Frequency 50 Hz*
Load Power Factor 0.8
Output/Waveform Sine wave
Typical Efficiency ≥82%
Load Current 6.1 A
Output Voltage Distortion with 100% Linear Load <3%
Overload Capacity (IT LOAD DISABLE) 100-120 % (3time auto reset) : 60sec
120-150 % (3time auto reset) : 30sec
150-200 %  : 2sec
200-300 %  : 1sec
300-400 % : 250ms
Overload Capacity (IT LOAD ENABLE) 100-110 % : 10 Min
110-120 % : 2 Min
120-150 % : 30sec
150-200 % : 2Sec
200-300 % : 1Sec
300-400 % : 250ms
Protection Overload, Battery Low, Battery High, Output Low, Output High, Output Short Ckt., Overheat, Under Frequency, Over Frequency, Solar Panel Reverse
LED Indication System ON, Inverter ON, SPV Charging, Grid Charging, Battery Low/High, Overload, Overheat, Mains Low, Mains High, Under Frequency, Over Frequency, NLSD
Switches Reset for System ON/OFF, UP, Down, Back, Enter(For LCD Calibration)
Display Battery Voltage, Charging Current, Discharging Current, Charging KWH, Discharging KWH, Solar Voltage, Solar Current, Instantaneous Power, Cumulative Power, Grid Voltage, Grid Current, Grid Frequency, Output Voltage, Output Current, Output Frequency

Environment

Operating Temperature 0-50°C
Cooling Fan
Max. Relative Humidity @25°C (non Condensing) 95%
Noise @ 1meter 55 db
Standard Compliance IP20
Dimension (LxWxH) Inch 15 X 11 X 14
Weight 27 Kg

FEATURES

Battery Health For Longer Life : Gamma PCU feeds the battery installed to it a constant boost charging current until its voltage reaches 14.2V and the float current (which is very close to zero) then maintains this voltage above 13V. Thus reducing the float current ( flowing for the longest period during the entire process) to zero, ultimately resulting in much enhanced battery life keeping it fully charged simultaneously.

Extensive electronic protections : There are a number of protections that Gamma PCU ensures. It stops reverse current flow from battery to solar array, it provides load short circuit protection, it provides Battery/Panel reverse protection through DC fuse,Overload protection, Input low/High, Output Low/High.

Utilizes maximum power available from the panel : Gamma PCU senses the point of maximum power available in the panel and charges the battery with this maximum power. Therefore, the battery is always charged with maximum possible power at any given time. This is the feature that allows your device to work to its full capacity and thus deliver the best possible results.

LCD display : Gamma PCU is available with LCD, for better user interface. It shows Battery voltage, charging current, discharging current, Output voltage , Output frequency, Output load percentage, Input voltage, Input frequency, Solar voltage, Solar current & Solar Power. It has for switches to configure Operational mode, No load shut down, Grid charger, IT Load, Input source.

Disclaimer: The Price & Specs Shown May Be Different From Actual. Please Confirm  Before Purchasing.