V-Guard DU 2500 comes with electrified transfer time speed mains to inverter and inverter to mains for quick charge and power back-up. It is flexible enough to adjust the backup time depending upon the connected load type. Also, its soft start feature with advanced level protection protects it from over charging, deep discharging, short circuits, main high, main low and thermal protection.
V-Guard DU 2500 is the superior most power backup device with efficient power management features that won’t let you down ever. Complements the serious business of computing and keeps the boost mode on for new age critical uninterrupted workflow needs. With its charging topology always on boost mode never go mad on last minute blink of power.
Specifications
Capacity | 2500VA / 2000W |
Nominal Output Voltage at No Load in Normal Mode | 220V + 5VAC |
Nominal Output Voltage at No Load in UPS Mode | 230V + 5VAC |
Nominal Output Voltage at No Load In High Performance Mode (Select By Cabinet Back Side Selection Switch) | 240V + 5VAC |
Output Waveform (Backup Mode) | Sine Wave |
Output Frequency (Backup Mode) | 50Hz + 0.5Hz (In Normal / UPS Mode) |
Normal Mode Mains Input Range in System ON Mode | 150V To 280V + 10V |
UPS Mode Mains Input Range in System ON Mode | 180V To 260V + 5V |
Output Voltage (ON Mains Mode) | Same as Input Voltage |
Normal Mode Input Frequency Range in System ON Mode | 43Hz To 57Hz + 0.5Hz |
UPS Mode Input Frequency Range in System ON Mode | 45Hz To 55Hz + 0.5Hz |
Normal Mode Transfer Time in System ON Mode | <40 ms |
UPS Mode Transfer Time in System ON Mode | <10 ms |
Recommended Battery | 12V / up to 180Ah, 4 No. |
Charging Current in Normal Charging Mode | 9A 1A DC (By Back Side Selection Switch) |
Charging Current in High Charging Mode | 11A 1A DC (By Back Side Selection Switch) |
Protections in Backup & Mains Mode | Overload, Short Circuit, Input, Battery Low Voltage, Mains Voltage Low/High, Mains Input Frequency Low/High Cut Off, Mains Fuse Blown, Heat Sink Over Temperature, Battery Over Charging |
LED Indications | For UPS Mode Selection, Mains ON, Battery Charging, Backup Mode, Battery Low, UPS Overload, UPS Output Short Circuit. Battery Water Topping, Inverter Switch ON & other faults with combinations of LED’s |
SHORT CIRCUIT PROTECTION | Provided with one retry |
Soft Start | Provided |
Generator Compatibility | Provided |
Warranty | 2 Years |
Features
- DSP based design
- High frequency design
- Intelligent audio & visual indications
- Advanced MOSFET based power stage with PWM output
- SMPS based smart charger*
- Quick battery charging mode
- Smart overload and short circuit protection
- Sine wave output
- Soft start facility
- Generator compatibility
- Intelligent thermal management
- Battery over charge & Deep discharge protection
- Selectable battery option
- Space saving design