Eastman 650VA PWM Solar Inverter Price Specification
Eastman 650VA PWM Solar Inverter Price Specification
Eastman offers a wide range of Off-Grid PWM based Solar PCU manufactured in India using world class technology platform and processes. Eastman’s Off-Grid PWM PCU is a powerful integrated machine consisting of an inverter, solar charge controller, AC charger and remote control (optional]. These smart Solar PCU’s are developed on advanced DSP based technology that makes them perfect for areas affected with frequent power cuts.
It provides operational flexibility to its users to enjoy the benefits of advanced monitoring and control features. The series adjusts itself to provide maximum performance in all weather conditions. It provides intelligent mixing of grid current with solar in case of solar energy shortfall during cloudy days. Eastman’s Off-Grid PWM PCU is perfect for installing in residential homes and commercial establishments.
Technology
- Charge Sharing from Solar & Grid
- Works as a Normal inverter if solar panels are not installed
- User Settable Modes – HC & Low Charging
- Grid Charging Enable Disable
Specification
Model No. | ESP650/12 |
Capacity | 650 VA |
In-built Solar Charge Controller
Maximum Input PV Voltage | 25 V |
Max Solar panel Wattage | Upto 600 Wp |
Battery Charging Current Imax. [From Solar + Grid] | 20 AMP |
Protection | Dver Current, Battery Dver Charge, PV Reverse Polarity, Reverse Current Flow |
Display Type | LCD Display |
Voltage Limits (UPS Mode)
Mains A.C. Low Cut | 180±10V |
Mains A.C. Low Cut Recovery | 190±10V |
Mains A.C. High Cut | 265±10V |
Mains A.C. High Cut Recovery | 255±10V |
Voltage Limits (Normal Mode]
Mains A.C. Low Cut | 180±10V |
Mains A.C. Low Cut Recovery | 110±10V |
Mains A.C. High Cut | 280±10V |
Mains A.C. High Cut Recovery | 270±10V |
AC Mains Made
Grid Input Range (UPS MOOE) | 180+10V – 265±10V |
Grid Input Range (Normal MODE] | 100+10V – 280±10V |
Grid charging current [TUB, FL, GEL, SMF]/HI | 16A/14A/16A/14A |
Grid charging current (TUB, FL, GEL, SMF]/LO | 12A/10A/10A/10A |
Boost Voltage (TUB, FL, GEL, SMF) | 14.4V/14.2V/14.2V/14.E+0.1V |
Float Voltage (TUB, FL, GEL, SMF] | 13.BV/13.6V/13.BV/13.B+0.1V |
Change over time Normal Mode (Mains – PCU) | +40ms |
Change over time Normal Mode (PCU – Mains] | +10ms |
Change over time UPS Mode
(Mains – PCU/PCU – Mains] |
^10ms |
Backup Mode [Solar Power Available/ Not Available]
Output Voltage Regulation (AC] [From Min. to Max. Battery voltage & No Load to Full Load) | 180V – 220V |
Nominal Input Batter voltage (DC) | 12V |
Battery Low Voltage warning | 10.8V±0.1V |
Battery Law Voltage Cut | 10.5V±0.1V |
Load Reconnect Voltage | 12.7±0.1V |
Short Circuit Protection | Provided |
Dver Load Protection (125%) | 6Sec. |
Dver Load Protection (15O%) | 2Sec. |
Dver Temp. Protection | Through Cooling Fan |
Features
- Pure sinewave output
- Advanced DSP based Technology LCD screen for user convenience
Intelligent Mixing of Grid Current with Solar in Case of Solar Energy Short fall During Cloudy Days - Solar Energy Usage always on first Priority
- Highest efficiency in its class
- Can Work As Normal Inverter If Solar Panels are not Installed
- Completely Safe : Overload,Protection,ShortCircuit Protection,Battery & PV Reverse Connection Protection