Luminous PCU NXT 3kW works on solar (when available), during this it charges the battery and drives load. When solar is not available the system transfers to grid and it charges the battery and drives load. In the event of power failure and solar is not available, the inverter transfers the load to the battery. The load is automatically transferred back to the mains or solar when it restores.3 kW solar PCU is Industrial design, heavy built for running power load such as 1 ton Inverter AC and lighting load such as fans, lights, computers, printers, Xerox machine used in home, office and commercial space.

Model Name NXT 3kW
Capacity (kW) 3
Nominal Battery Voltage (Vdc) 48 V
Output Waveform Sine wave

SOLAR PHOTOVOLTAIC INPUT

Type of Charger MPPT
Maximum PV power (kW) 3300 Watt
Input Voltage range (Voc) 80 – 165
Input Voltage range (Vmp) 65 – 130

GRID INPUT

Input Supply Phases Single Phase
Nominal Voltage & Voltage range 230V AC (185V – 265V)
Nominal Frequency & Range 50 Hz

BATTERY

Battery recharge current range from Grid Side (A) 0 – 30
Battery recharge current range from Array Side (A) 0 – 60
Charging Stages Float, Bulk, Boost

UPS

Switching Element MOSFET
Control 32 Bit DSP controlled
Nominal Output VAC 230 V
Output waveform Pure Sine Wave
Nominal Frequency 50 Hz
Power Factor 0.8 lag to 0.8 lead
Nominal Output Current (A) 13
Overload at nominal output voltage 110% for 10 Minutes, 200% for 5 Secs

SYSTEM DATA

Noise @ 1 meter (dBA ± 2dBA) <58dBA
Transfer Time <20 mS
Protection Under/Over voltage protection for Input, Output, Battery & Array; Reverse polarity protection for Array & Battery; Protection for Output Overload, Short circuit and Over Temperature; MCB & Surge protection at Grid/DG Input, Battery, Array Path and PCU O/P
Display Parameters Voltage/Current: Array, Battery, Grid, Output; Day kWh, Cumulative kWh, Date, Time
Indications Battery Charging/ Discharging, Grid ON, Load ON, UPS ON, Array ON, Fault LED Indicator (For Overload, Low Battery, Over Temperature),
Setting Battery type, Battery voltage (Boost & Float), Priority (SGB/SBG), Charging Current from Grid

ENVIRONMENT

IP Protection Level IP-21
Operating Temperature (˚C) 0-50 °C without any degradation
Max. Relative humidity @ 25˚C Up to 95% (non-condensing)
Max. Altitude above sea level without de-rating (m) 1000m

STANDARD COMPLIANCE

Certifications IEC 61683, IEC 60068-2(1,2 14, 30)

GENERAL

Dimension (W*D*H) [mm] 300x504x515
Net Weight (Kg) 50

 