Eastman EGP1800 24V Solar Off Grid PCU Price Specifications
Eastman EGP1800 24V Solar Off Grid PCU Price Specifications
Eastman self-sustaining PMW PCU has been manufactured by using world-class technology platform and process as an efficient solution for areas struggling with frequent power cuts. It can be used for domestic, industrial and other events. It provides clean energy for residential and industrial areas without any residual effect. It has a self-adjustable setting which provides superlative performance in all weather conditions. It has profound mixing of grid current with solar in case of solar energy insufficiency during cloudy days. It consists an inverter, solar charge controller, AC charger and remote control (optional).
Eastman Off-Grid PWM PCU is superb for installation in petrol pumps, gas stations, schools, commercial, and residential applications. How Does It Work : In Solar Off-grid PWM PCU, when the sun rays hit on the solar panel, it leads to the generation of DC power which converted usable AC power for the functioning of the connected appliances. The surplus DC power is secured in the battery in case of power cut. The solar charger controller which is inbuilt insure appropriate battery charging and restrain the reverse flow of current to the solar panel. PWM means Pulse Width Modulation which is used as one method of float charging. It sends out a series of short charging pulse to the battery- a very rapid “on-off” switch. The controller continually checks the condition of the battery.
Eastman EGP1800 Specifications
Model No | EGP1800 |
Capacity | 1500 VA |
Operating DC Voltage | 24V |
Switching Element | Mosfet |
Charger Topology | Boost Mosfet |
Parameters (Grid)
Default Value | Variable Range | |
Nominal Grid Voltage | 230V | |
Battery Low Buzzer | 10.8V | Battery Low Cut +0.3V |
Battery Low Cut | 10.5V | 10V-11.5V |
Battery High Cut | 16.5V | 16.5V-17.5V |
SPV Charging Voltage (Boost) SMF/TUB | 13.7V / 15V | 13.5V-14.5V / 14.2V-15.5V |
SPV Charging Voltage (Float) SMF/TUB | 13.7V / 14.2V | 13.5V-13.7V / 13.8V-14.5V |
Grid Charging Voltage (Boost) SMF/TUB | 13.5V / 14.5V | NA / 13.8V-15V |
Grid Charging Voltage (Float) SMF/TUB | 13.5V / 13.8V | NA / 13V-14.2V |
Grid Charging Voltage (Equalize) | After 30 Days | NA |
Grid Charging Current | 12A / 15A | 5A – 20A |
Grid Reconnect @ Battery Voltage | 11.8 V | 11V – 12V |
Grid Low Cut Voltage IT Mode Enable / Disable | 170V±10V / 100V±10V | |
Grid Low Cut Recovery IT Mode Enable / Disable | 180V±10V / 110V±10V | |
Grid High Cut Voltage IT Mode Enable / Disable | 265V±10V / 290V±10V | |
Grid High Cut Recovery IT Mode Enable / Disable | 255V±10V / 280V±10V | |
Changeover (Batt. to Mains) IT Mode Enable/Disable | <5ms | |
Changeover (Mains to Batt.) IT Mode Enable/Disable | <12ms |
Parameters (Inverter)
Output Phase | 1 Phase |
Nominal.Output.Voltage | 220V±8% |
Max. Output Current | 4.3A |
Nominal Frequency | 50Hz±1% |
Output Waveform | Sinewave |
Typical Efficiency | ≥85% |
Voltage Harmonic | <3% (Linear Load) |
Over Load Capacity | IT Mode Disable : – >110% 3Time Auto Reset, 4th Time Shut Down. Note : 1HP Motor Load Run for 15min in 2050 & 2550 Model. |
IT Mode Enable : >110% 1st Time Shut Down | |
>150% Output Goes Down | |
Motor 1HP | NA |
Protection | Overload, Battery Low, Battery High, Output Short Ckt., Battery Reverse,Over Heat, Over frequency, Under Frequency, SPV High. |
LED Indication | System ON, (IT Mode, SMF/TUB, Boost Chg., DG Mode, Grid Chg.) Enable/Disable |
Switches | Reset for System ON/OFF, UP, Down, Back, Enter(For LCD Calibration) |
Display | Battery Voltage, Charging Current, Grid Voltage, Grid Frequency, Output Voltage, Output
Frequency, Load%, Battery Graph, Overheat, SPV Current, Working Mode(HYB/PCU/SMT). |
Parameters (Solar)
Switching Element | Mosfet |
Controller | Yes |
Type of Charger | PWM |
Efficiency | ≥95% |
Solar Current MIN. | >3A (Below 3A, System will act like Solar Absent) |
Solar Current MAX. | 50A |
Input Voltage Range (Min – Max)Voc | 31V-45V |
Maximum PV Power Recommended | (315W/320W/325W) x 4 |
Parameters (Environment)
Operating Temperature | 0-50°C |
Cooling | Fan |
Max. Relative Humidity @25°C (non Condensing) | 95% |
Noise @ 1meter | 50dB |
Standard Compliance | IP20 |
Weight (kg) | 15 |
Dimension L x W x H(mm) | 300x265x165 |
Features
• High Speed Micro Controller based Solar Home UPS.
• Built in Solar Charge Controller.
• Multi-colour LCD Display.
• Freq.:- Available – 50Hz & 60Hz.
• Charging Multi Stage (Bulk, Absorption & Float).
• Solar Priority of load & battery charging.
• Preference to Solar Power over Grid Power.
• Pure sine wave output.
• Protections : RBP, RSPV, OVL, BL, OBC, SC, IHV & ILV.
• Compatible with DG as an Input Source.
• Compatible with IT Load.
• Compatible with SMF, Gel & Tubular Batteries.
• Priority Selection – PCU, Smart & Hybrid for Saving Energy and Money.
Note : Specification are subject to change without prior notice due to constant improvement in design & technology.
Sir मेरे पास ईस्टमैन का सोलर इन्वर्टर ह परंतु सोलर से बैट्री चार्ज नहीं कर रहा जानकारी उपलब्ध कराने का कष्ट करे
aapke panel se kam power aa rahi hogi ya aapki battery kharab hogi