Powered by Smarten’s solar panels, the BOOM Solar PCU provides a power saving of 30%, and charges at even low voltages like 90V. With a 10ms changeover time, triple protection and an 88% system efficiency, BOOM helps you to enjoy continuous power even during extended power cuts, and makes you lesser dependent on the power grid.
UPS
Output voltage | 220 V ± 5 % |
Output frequency | 50 Hz |
Output waveform | Pure Sine wave ≤ 5% THD |
No Load current | 1.3 ± .3 Amp. |
Capacity Resistive Bulb Load | 1300 Watt |
Discharging current @ full load | 55 ± 2 Amp. |
Low Battery Warning | 21.6V ± 0.2 V |
Low Battery Cut | 20.8 ± 0.2 V |
Change over time UPS mode | < 10 msec |
Change over time WUPS mode | < 25 msec |
Short circuit | System shut down in 3 tries |
Grid
Mains AC low cut UPS mode | 175 VAC ± 10 V |
Mains AC low cut recovery UPS mode | 185 VAC ± 10 V |
Mains AC high cut UPS mode | 265 VAC ± 10 V |
Mains AC high cut recovery UPS mode | 255 VAC ± 10 V |
Mains AC low cut WUPS mode | 90 VAC ± 10 V |
Mains AC low cut recovery WUPS mode | 110 VAC ± 10 V |
Mains AC high cut WUPS mode | 295 VAC ± 10 V |
Mains AC high cut recovery WUPS mode | 285 VAC ± 10 V |
Input Frequency Range | 40 Hz to 60 Hz |
Voltage Output in Mains Mode | Same as input |
Frequency Output in Mains Mode | Same as input |
Battery
DC input voltage | 24 V |
Battery Qty. 12V 100Ah-220Ah | 2 |
Float charging voltage | 27.4± 0.2V |
Boost volt. for TUB and SMF battery | 29 ± 0.2V |
Boost charging voltage for LA Battery | 28 ± 0.2V |
Charging Current 100Ah-135Ah Setting | 12A ± 2 A |
Charging Current 150Ah-220Ah Setting | 15A ± 2 A |
Charging current 1/Prange(90V-295V/AC | 5A ± 2 A |
Solar Panel
Input PV voltage range | 28 V – 56V |
Maximum PV charging current | 50 A |
Panel capacity | 1500 W |
High PV range | 58V |
Reverse PV | Protection Given |
Protection
Overload in backup mode | System will run 100% load continuously but more then 100% system will shut down within(10-15) seconds |
Overload in backup mode | System will shut down within 3 tries |
Short Circuit in Mains Mode | System will show mains fuse blown indication |
Over temperature | Above 100°C temperature system will shut down |
Reverse Battery | DC fuse will blown |