Powered by Smarten’s high quality solar panels, the SAVER Solar PCU provides a power saving of 30%, and charges at even low voltages like 90V. With a 10ms changeover time, triple protection and an 88% system efficiency, SAVER helps you to enjoy continuous power even during extended power cuts, and makes you lesser dependent on the power grid.

UPS

Output voltage 220 V ± 5 %
Output frequency 50 Hz
Output waveform Pure Sine wave ≤ 5% THD
No Load current 1.3 ± .3 Amp.
Capacity Resistive Bulb Load 7500 Watt
Discharging current @ full load 62 ± 2 Amp.
Low Battery Warning 106 ± 0.2 V
Low Battery Cut 104  ± 0.2 V
Change over time UPS mode < 10 msec
Change over time WUPS mode < 25 msec
Short circuit System shut down in 3 tries

Grid

Mains AC low cut UPS mode 175 VAC ± 10 V
Mains AC low cut recovery UPS mode 185 VAC ± 10 V
Mains AC high cut UPS mode 265 VAC ± 10 V
Mains AC high cut recovery UPS mode 255 VAC ± 10 V
Mains AC low cut WUPS mode 90 VAC ± 10 V
Mains AC low cut recovery WUPS mode 110 VAC ± 10 V
Mains AC high cut WUPS mode 295 VAC ± 10 V
Mains AC high cut recovery WUPS mode 285 VAC ± 10 V
Input Frequency Range 40 Hz to 60 Hz
Voltage Output in Mains Mode Same as input
Frequency Output in Mains Mode Same as input

Battery

DC input voltage 120 V
Battery Qty. 12V 100Ah-220Ah 10
Float charging voltage 135 ± 0.2V
Boost volt. for TUB and SMF battery 145 ± 0.2V
Boost charging voltage for LA Battery 140± 0.2V
Charging Current 100Ah-135Ah Setting 12A ± 2 A
Charging Current 150Ah-220Ah Setting 15A ± 2 A
Charging current 1/Prange(90V-295V/AC 5A ± 2 A

Solar Panel

Input PV voltage range 260 V
Maximum PV charging current 50 A
Panel capacity 8000 W
High PV range 265 V
Reverse PV Protection Given

Protection

Overload in backup mode System will run 100% load continuously but more then 100% system will shut down within (10-15)
seconds
Overload in backup mode System will shut down within 3 tries
Short Circuit in Mains Mode System will show mains fuse blown indication
Over temperature Above 100°C temperature system will shut down
Reverse Battery DC MCB Protection

 