Solar Inverter

Smarten Saver 1700 VA Solar Inverter PCU Price in India

Smarten Saver 1700 VA Solar Inverter PCU Price in India

The premium, technically advanced SAVER Solar PCU with technology from Germany and Taiwan combines the functions of a solar inverter and UPS, and completely cancels the need to maintain separate power back up systems for powering equipments and computers.

Powered by Smarten’s high quality solar panels, the SAVER Solar PCU provides a power saving of 30%, and charges at even low voltages like 90V. With a 10ms changeover time, triple protection and an 88% system efficiency, SAVER helps you to enjoy continuous power even during extended power cuts, and makes you lesser dependent on the power grid.

UPS

Output voltage 220 V ± 5 %
Output frequency 50 Hz
Output waveform Pure Sine wave ≤ 5% THD
No Load current 1.3 ± .3 Amp.
Capacity Resistive Bulb Load 1200 Watt
Discharging current @ full load 50 ± 2 Amp.
Low Battery Warning 21 ± 0.2 V
Low Battery Cut 20.8 ± 0.2 V
Change over time UPS mode < 10 msec
Change over time WUPS mode < 25 msec
Short circuit System shut down in 3 tries

Grid

Mains AC low cut UPS mode 175 VAC ± 10 V
Mains AC low cut recovery UPS mode 185 VAC ± 10 V
Mains AC high cut UPS mode 265 VAC ± 10 V
Mains AC high cut recovery UPS mode 255 VAC ± 10 V
Mains AC low cut WUPS mode 90 VAC ± 10 V
Mains AC low cut recovery WUPS mode 110 VAC ± 10 V
Mains AC high cut WUPS mode 295 VAC ± 10 V
Mains AC high cut recovery WUPS mode 285 VAC ± 10 V
Input Frequency Range 40 Hz to 60 Hz
Voltage Output in Mains Mode Same as input
Frequency Output in Mains Mode Same as input

Battery

DC input voltage 24 V
Battery Qty. 12V 100Ah-220Ah 2
Float charging voltage 27.4  ± 0.2V
Boost volt. for TUB and SMF battery 29 ± 0.2V
Boost charging voltage for LA Battery 28± 0.2V
Charging Current 100Ah-135Ah Setting 12A ± 2 A
Charging Current 150Ah-220Ah Setting 15A ± 2 A
Charging current 1/Prange(90V-295V/AC 5A ± 2 A

Solar Panel

Input PV voltage range 56V
Maximum PV charging current 50 A
Panel capacity 2000 W
High PV range 58V
Reverse PV Protection Given

Protection

Overload in backup mode System will run 100% load continuously but more then 100% system will shut down within (10-15)
seconds
Overload in backup mode System will shut down within 3 tries
Short Circuit in Mains Mode System will show mains fuse blown indication
Over temperature Above 100°C temperature system will shut down
Reverse Battery DC fuse will blown

 

Disclaimer: The Price & Specs Shown May Be Different From Actual. Please Confirm  Before Purchasing.

Related Articles

Leave a Reply

Your email address will not be published. Required fields are marked *

Back to top button