Solar Inverter

Smarten Superb 1100 Mppt PCU Price in India

Smarten Superb 1100 Mppt PCU Price in India

Made with high grade quality, technically advanced Superb Solar PCU is an innovative solar inverter, that gives you the joy of uninterrupted power supply. It’s is packed with exciting features like LCD Screen, Advanced DSP Controller and more.

Backed by Smarten’s impeccable solar panels, the Superb PCU is 30% more efficient than usual PCUs. It comes with 4 levels of battery’s depth of discharge options for your different power requirements. With low voltages charging, 10 ms changeover time and triple protection, it completely cancels the need to maintain separate power back up system for powering equipment.

UPS

Capacity 1 Kva
Output frequency 50 Hz
Output waveform Pure Sine wave ≤ 5% THD
No Load current 1.3 ± .3 Amp.
Output voltage 220 V ± 5 %
Discharging current @ full load 50 ± 2 Amp.
Low Battery Warning 11 ± 0.2 V
Low Battery Cut 10.6 ± 0.2 V
Change over time UPS mode < 10 msec
Change over time WUPS mode < 25 msec
Short circuit System shut down in 3 tries

Grid

Mains AC low cut UPS mode 175 VAC ± 10 V
Mains AC low cut recovery UPS mode 185 VAC ± 10 V
Mains AC high cut UPS mode 265 VAC ± 10 V
Mains AC high cut recovery UPS mode 255 VAC ± 10 V
Mains AC low cut WUPS mode 90 VAC ± 10 V
Mains AC low cut recovery WUPS mode 110 VAC ± 10 V
Mains AC high cut WUPS mode 295 VAC ± 10 V
Mains AC high cut recovery WUPS mode 285 VAC ± 10 V
Input Frequency Range 40 Hz to 60 Hz
Voltage Output in Mains Mode Same as input
Frequency Output in Mains Mode Same as input

Battery

DC input voltage 12 V
Battery Qty. 12V 100Ah-220Ah 1
Float charging voltage 13.5 ± 0.2V
Boost volt. for TUB and SMF battery 14.5 ± 0.2V
Boost charging voltage for LA Battery 14 ± 0.2V
Charging Current 100Ah-135Ah Setting 12A ± 2 A
Charging Current 150Ah-220Ah Setting 15A ± 2 A
Charging current 1/Prange(90V-295V/AC 5A ± 2 A

Solar Panel

Input PV voltage range 50V
Maximum PV charging current 30 A
Panel capacity 540 W
High PV range 25V ±  2V
Reverse PV Protection Given

Protection

Overload in backup mode System will run 100% load continuously but more then 100% system will shut down within(1-15)
seconds
Overload in backup mode System will shut down within 3 tries
Short Circuit in Mains Mode System will show mains fuse blown indication
Over temperature Above 100°C temperature system will shut down
Reverse Battery DC fuse will blown

 