V-Guard DU 5500 Inverter Price In India
V-Guard DU 5500 Inverter Price In India
Never experience a downtime just when the mission critical assignment is round the corner or a project is on a verge of completion. V-Guard DU 5500 is a high capacity 5500 VA powerhouse that extends support when it is needed the most. It has soft boot on, thermal protective feature with in-built threshold. That leaves you less worried about weather conditions.
Unwrap the world of features which includes protection from mains low, mains high, thermal protection, deep discharge or over charge, over load or short circuit. V-Guard DU 5500 is the faster than any other inverter to charge the battery with power transfer from mains to inverter and inverter to mains being quicker. For uninterrupted operation cycles, whether you are looking to run a gaming studio or gearing up to install a series of turnkey workstations, V-Guard DU 5500 is the key to unstoppable awe!
Specifications
Capacity | 5500VA / 4400W |
Nominal Output Voltage at No Load in Normal Mode | 220V + 5VAC |
Nominal Output Voltage at No Load in UPS Mode | 230V + 5VAC |
Nominal Output Voltage at No Load In High Performance Mode (Select By Cabinet Back Side Selection Switch) | 240V + 5VAC |
Output Waveform (Backup Mode) | Sine Wave |
Output Frequency (Backup Mode) | 50Hz + 0.5Hz (In Normal / UPS Mode) |
Normal Mode Mains Input Range in System ON Mode | 150V To 280V + 10V |
UPS Mode Mains Input Range in System ON Mode | 180V To 260V + 5V |
Output Voltage (ON Mains Mode) | Same as Input Voltage |
Normal Mode Input Frequency Range in System ON Mode | 43Hz To 57Hz + 0.5Hz |
UPS Mode Input Frequency Range in System ON Mode | 45Hz To 55Hz + 0.5Hz |
Normal Mode Transfer Time in System ON Mode | <40 ms |
UPS Mode Transfer Time in System ON Mode | <10 ms |
Recommended Battery | 12V / up to 180Ah, 8 No. |
Charging Current in Normal Charging Mode | 9A 1A DC (By Back Side Selection Switch) |
Charging Current in High Charging Mode | 11A 1A DC (By Back Side Selection Switch) |
Protections in Backup & Mains Mode | Overload, Short Circuit, Input, Battery Low Voltage, Mains Voltage Low/High, Mains Input Frequency Low/High Cut Off, Mains Fuse Blown, Heat Sink Over Temperature, Battery Over Charging |
LED Indications | For UPS Mode Selection, Mains ON, Battery Charging, Backup Mode, Battery Low, UPS Overload, UPS Output Short Circuit. Battery Water Topping, Inverter Switch ON & other faults with combinations of LED’s |
SHORT CIRCUIT PROTECTION | Provided with one retry |
Soft Start | Provided |
Generator Compatibility | Provided |
Warranty | 2 Years |
Features
- DSP based design
- High frequency design
- Intelligent audio & visual indications
- Advanced MOSFET based power stage with PWM output
- SMPS based smart charger*
- Quick battery charging mode
- Smart overload and short circuit protection
- Sine wave output
- Soft start facility
- Generator compatibility
- Intelligent thermal management
- Battery over charge & Deep discharge protection
- Selectable battery option
- Space saving design
Disclaimer: The Price & Specs Shown May Be Different From Actual. Please Confirm Before Purchasing.