Waaree WEM Solar Off-Grid PCU (Power Conditioning Unit) is an integrated unit consists of grid charger, inverter, MPPT Solar Charger. It continuously monitors Battery and Solar voltage as well as Grid and Output voltage with their currents. MPPT based solar charger extracts the maximum power from the solar panels whereby it increases the efficiency of the system. MPPT charger has multistage charging which maintains the battery charging voltage such that it increases the lifespan of battery.
PCU from the house of Waaree has the intelligent feature to recognize the type of battery connected to it. It may be an ordinary battery or a branded one, a tubular battery or a sealed one. No matter what the type, it auto adjusts the battery’s charging characteristics accordingly. Even those batteries which cease to go over 13.5V after a while of use work flawlessly with Waaree ’s Home UPS.
Specifications
PCU Capacity – W | 3500 watt |
Charge Controller Type | MPPT |
Max PV input Power – Wp | 3750 watt |
Max Solar Input Current – Amp | 25.5 |
Max Current from Battery – Amp | 63 |
Charge Controller Type | One Input Dual Channel Interleaved MPPT |
Max Solar Input Voltage Vmp) – V | 150 |
Max Solar DC Input Voltage (Voc) – V | 185 |
Solar Battery Charging Current | 40 Amps. Default Settable from 5 to 50 Amps for battery |
Charging Efficiency | 98% |
Battery Mode
No Load Current (Switch OFF) – mA | ≤ 180 |
Nominal Battery Voltage – V | 48 |
Output Voltage at No LOAD – V | 230 ± 1% |
Output Frequency @ No LOAD – Hz | 50 ± 1% |
Output Frequency @ Full LOAD – Hz | 50 ± 1% |
Short Circuit | > 300 % |
Voltage THDi (linear load) | ≤ 3 % |
UPS Mode
Low Cut With Phase Match – V | 180 ± 5 |
High Cut With Phase Match – V | 260 ± 5 |
Change Over Time From Mains To UPS | ≤ 10 Msec |
Change Over Time From UPS To Mains | ≤ 10 Msec |
Normal Mode
Low Cut With Phase Match – V | 100 ± 5 |
High Cut With Phase Match – V | 280 ± 5 |
Change Over Time From Mains To UPS | ≤ 40 Msec |
Change Over Time From UPS To Mains | ≤ 10 Msec |
Charging Mode
Low Charging Current @ 220V AC (NC) – Amp | 12 ± 1 A |
High Charging Current @ 220V AC (HC) – Amp | 16 ± 1 A |
Boost Charging Voltage (HC/NC) – V | 14.4 ± 0.2 (Per Battery) |
Float Charging Voltage (HC/NC) – V | 13.7 ± 0.2 (Per Battery) |
Protections
Overload Protection with Alarm | Over Load shutdown After 6 Auto Retries |
Overload Shutdown Reset | Through ON/Of Switch & Mains |
Battery Low Alarm | 10.8 ± 0.2 V (Per Battery) |
Battery Low Protection | Battery Low shutdown after 4 Auto retires |
Battery Low Shutdown Reset | Through ON/Of Switch & Mains |
Over Temperature Protection With Alarm | 95 ± 5 °C |
Short Circuit @ Mains Mode | AC Fuse |
Short Circuit Protection (Battery Mode) | Yes |
Short Circuit Retry | One |
Short Circuit Reset | Through ON/Of Switch & Mains |
P.V. reverse protection with alarm | Yes |
Remote Monitoring | yes (Optional) |
Features
- Power Saving feature to bypass charging from grid to save on electricity bills
- Real time divides the day in 4 time slots for optimum solar power utilization
- MPPT built-in Solar Charge controllers
- Solar Power is an optional feature, so it can be used as a conventional Inverter
- Smart Overload, Short circuit sensing and protection circuits with auto retry
- Provision for setting critical parameters
- Priority Selection for Battery Charging
- Instant Changeover to support computers, servers & sensitive loads
- Independent of grid, Grid is not mandatory
- LCD Display to read and edit the parameters
** Refer to Waaree’s Warranty Document for Terms & Conditions.
*The Specifications are for the reference purpose only.
>Waaree reserves the right to change the specifications without prior notice.
Disclaimer: The Price & Specs Shown May Be Different From Actual. Please Confirm Before Purchasing.