Solar Inverter

Waaree WEM 5000 Solar Off-Grid PCU Price Specifications

Waaree WEM 5000 Solar Off-Grid PCU Price Specifications

Waaree WEM Solar Off-Grid PCU (Power Conditioning Unit) is an integrated unit consists of grid charger, inverter, MPPT Solar Charger. It continuously monitors Battery and Solar voltage as well as Grid and Output voltage with their currents. MPPT based solar charger extracts the maximum power from the solar panels whereby it increases the efficiency of the system. MPPT charger has multistage charging which maintains the battery charging voltage such that it increases the lifespan of battery.

PCU from the house of Waaree has the intelligent feature to recognize the type of battery connected to it. It may be an ordinary battery or a branded one, a tubular battery or a sealed one. No matter what the type, it auto adjusts the battery’s charging characteristics accordingly. Even those batteries which cease to go over 13.5V after a while of use work flawlessly with Waaree ’s Home UPS.

Specifications

PCU Capacity – W 5000 watt
Charge Controller Type MPPT
Max PV input Power – Wp 5000 watt
Max Solar Input Current – Amp 34
Max Current from Battery – Amp 84
Charge Controller Type Two Input Dual Channel Interleaved MPPT
Max Solar Input Voltage Vmp) – V 150
Max Solar DC Input Voltage (Voc) – V 185
Solar Battery Charging Current 40 Amps. Default Settable from 5 to 50 Amps for battery
Charging Efficiency 98%

Battery Mode

No Load Current (Switch OFF) – mA ≤ 180
Nominal Battery Voltage – V 48
Output Voltage at No LOAD – V 230 ± 1%
Output Frequency @ No LOAD – Hz 50 ± 1%
Output Frequency @ Full LOAD – Hz 50 ± 1%
Short Circuit > 300 %
Voltage THDi (linear load) ≤  3 %

UPS Mode

Low Cut With Phase Match – V 180 ± 5
High Cut With Phase Match – V 260 ± 5
Change Over Time From Mains To UPS ≤  10 Msec
Change Over Time From UPS To Mains ≤  10 Msec

Normal Mode

Low Cut With Phase Match – V 100 ± 5
High Cut With Phase Match – V 280 ± 5
Change Over Time From Mains To UPS ≤  40 Msec
Change Over Time From UPS To Mains ≤  10 Msec

Charging Mode

Low Charging Current @ 220V AC (NC) – Amp 12 ±  1 A
High Charging Current @ 220V AC (HC) – Amp 16 ±  1 A
Boost Charging Voltage (HC/NC) – V 14.4 ±  0.2 (Per Battery)
Float Charging Voltage (HC/NC) – V 13.7 ± 0.2 (Per Battery)

Protections

Overload Protection with Alarm Over Load shutdown After 6 Auto Retries
Overload Shutdown Reset Through ON/Of Switch & Mains
Battery Low Alarm 10.8 ± 0.2 V (Per Battery)
Battery Low Protection Battery Low shutdown after 4 Auto retires
Battery Low Shutdown Reset Through ON/Of Switch & Mains
Over Temperature Protection With Alarm 95 ± 5 °C
Short Circuit @ Mains Mode AC Fuse
Short Circuit Protection (Battery Mode) Yes
Short Circuit Retry One
Short Circuit Reset Through ON/Of Switch & Mains
P.V. reverse protection with alarm Yes
Remote Monitoring yes (Optional)

Features

  • Power Saving feature to bypass charging from grid to save on electricity bills
  • Real time divides the day in 4 time slots for optimum solar power utilization
  • MPPT built-in Solar Charge controllers
  • Solar Power is an optional feature, so it can be used as a conventional Inverter
  • Smart Overload, Short circuit sensing and protection circuits with auto retry
  • Provision for setting critical parameters
  • Priority Selection for Battery Charging
  • Instant Changeover to support computers, servers & sensitive loads
  • Independent of grid, Grid is not mandatory
  • LCD Display to read and edit the parameters

** Refer to Waaree’s Warranty Document for Terms & Conditions.
*The Specifications are for the reference purpose only.
>Waaree reserves the right to change the specifications without prior notice.