Luminous PCU NXT 3kW/48V Single Phase Solar PCU
Luminous PCU NXT 3kW/48V Single Phase Solar PCU
Luminous PCU NXT 3kW works on solar (when available), during this it charges the battery and drives load. When solar is not available the system transfers to grid and it charges the battery and drives load. In the event of power failure and solar is not available, the inverter transfers the load to the battery. The load is automatically transferred back to the mains or solar when it restores.3 kW solar PCU is Industrial design, heavy built for running power load such as 1 ton Inverter AC and lighting load such as fans, lights, computers, printers, Xerox machine used in home, office and commercial space.
Model Name | NXT 3kW |
Capacity (kW) | 3 |
Nominal Battery Voltage (Vdc) | 48 V |
Output Waveform | Sine wave |
SOLAR PHOTOVOLTAIC INPUT
Type of Charger | MPPT |
Maximum PV power (kW) | 3300 Watt |
Input Voltage range (Voc) | 80 – 165 |
Input Voltage range (Vmp) | 65 – 130 |
GRID INPUT
Input Supply Phases | Single Phase |
Nominal Voltage & Voltage range | 230V AC (185V – 265V) |
Nominal Frequency & Range | 50 Hz |
BATTERY
Battery recharge current range from Grid Side (A) | 0 – 30 |
Battery recharge current range from Array Side (A) | 0 – 60 |
Charging Stages | Float, Bulk, Boost |
UPS
Switching Element | MOSFET |
Control | 32 Bit DSP controlled |
Nominal Output VAC | 230 V |
Output waveform | Pure Sine Wave |
Nominal Frequency | 50 Hz |
Power Factor | 0.8 lag to 0.8 lead |
Nominal Output Current (A) | 13 |
Overload at nominal output voltage | 110% for 10 Minutes, 200% for 5 Secs |
SYSTEM DATA
Noise @ 1 meter (dBA ± 2dBA) | <58dBA |
Transfer Time | <20 mS |
Protection | Under/Over voltage protection for Input, Output, Battery & Array; Reverse polarity protection for Array & Battery; Protection for Output Overload, Short circuit and Over Temperature; MCB & Surge protection at Grid/DG Input, Battery, Array Path and PCU O/P |
Display Parameters | Voltage/Current: Array, Battery, Grid, Output; Day kWh, Cumulative kWh, Date, Time |
Indications | Battery Charging/ Discharging, Grid ON, Load ON, UPS ON, Array ON, Fault LED Indicator (For Overload, Low Battery, Over Temperature), |
Setting | Battery type, Battery voltage (Boost & Float), Priority (SGB/SBG), Charging Current from Grid |
ENVIRONMENT
IP Protection Level | IP-21 |
Operating Temperature (˚C) | 0-50 °C without any degradation |
Max. Relative humidity @ 25˚C | Up to 95% (non-condensing) |
Max. Altitude above sea level without de-rating (m) | 1000m |
STANDARD COMPLIANCE
Certifications | IEC 61683, IEC 60068-2(1,2 14, 30) |
GENERAL
Dimension (W*D*H) [mm] | 300x504x515 |
Net Weight (Kg) | 50 |
Tags : luminous solar hybrid pcu nxt 3kw manual luminous 3kw solar combo luminous nxt 3kw 3kw off grid solar inverter price in india luminous nxt 3kw luminous 3kw solar inverter luminous solar pcu 3kw luminous 3kva solar inverter